Find your DEGASi Degasser

Degasser

Systec AF™ Internal Volume

No of Channels

Biocompatible Flow Path

Approximate Max Flow
Per Channel (ml/min)

Inner Dimension Flow Path (mm)

DEGASi PLUS
CLASSIC


Biotech DEGASi Plus Classic degasser

480 µl

1-6

Yes

3

1.14





Add to quote
DEGASi PLUS
GPC


Biotech DEGASi PLUS GPC 2 degasser

480 µl

1-6

No, Stented

3

1.14

DEGASi PLUS
MICRO


Biotech DEGASi Plus MICRO degasser

100 µl

1-6

Yes

0.5

1.14

DEGASi PLUS
SEMI-PREP


Biotech DEGASi PLUS SEMI-PREP degasser

925 µl

1-6

Yes

6

1.14

DEGASi PREP

Biotech DEGASi PREP degasser

5.3 ml

2

No

15

1.91

DEGASi PREP+
Biotech Degassi-Prep-Plus degasser

23 ml

1, 2 or 4

Yes

75-100

N/A

DEGASi COMPACT

Biotech DEGASi COMPACT degasser

285 µl

2, 4, 6

Yes

2

0.89

DEGASi HIGH FLOW 1000
Biotech DEGASi HIGH-FLOW degasser

200 ml (silicone)

1

Yes

500

N/A

  • Suitable for high flow applications like chemical analyses, biotechnology or sensitive processes on the manufacturing side. DEGASi® HIGH FLOW 1000 works with real high flow rates and ultra-high degassing efficiency. With water-based solutions it removes dissolved gases at flow rates up to 1000 ml/min. See Solvent Compatibility Chart »
  • DEGASi® Prep+ uses a revolutionary new technology that makes it possible to degas organic solutions at higher flow rates in a cost-effective manner. That means you can get increased capacity at a lower price. DEGASi® Prep+ is a perfect choice for efficient degassing of many types of liquids at high flow rates, up to 75-100 mL /min per chamber. It is compatible with aqueous-organic liquids and alkanes, but not aggressive solvents like HFIP. The DEGASi® Prep+ degassers is available in different models with 1, 2, or 4 channels. In its standard configuration with 1/4-28 flat-bottom ports for 1/8” OD tubing, flow rates up to 75 mL/min can be degassed. The DEGASi® Prep+ Large and DEGASi® Prep+ XLarge, are instead configured for 3/16″ (4.8 mm) and 1/4″ (6.4 mm) OD tubing, respectively, and can handle flow rates up to 100 mL/min. The unique DEGASi® Prep+ AUX degasser configuration is designed for flow rates up to 75-100 mL/min, and is also equipped with one additional auxiliary degassing channel of your choice for analytical flow rates.
  • Our Preparative Stand Alone Vacuum Degasser Systems are specifically designed for HPLC and other fluidic systems. The DEGASi PREP series is designed for flowrates from 15-50ml/min per channel. The system removes dissolved gases from the mobile phases to reduce retention time shifts and improve baseline stability, as the pump will work much more reliable. Removing dissolved gasses eliminates bubbles before they occur and removes oxygen which can interfere with UV detection methods.
  • Stand Alone Vacuum Degasser Systems are specifically designed for HPLC and other fluidic systems. The system removes dissolved gases from the mobile phases to reduce retention time shifts and improve baseline stability. Removing dissolved gasses eliminates bubbles before they occur and removes oxygen which can interfere with UV detection methods. The system is available in 2-5 channel systems at analytical flow rates and preparative up to 100mL/min per channel. Select the "GPC" version for applications using hexanes and similar organic solvents. See Solvent Compatibility Chart »
  • The new Stand Alone Vacuum Degasser Systems are specifically designed for HPLC, SPR and other fluidic systems. The system removes dissolved gases from the mobile phases to reduce retention time shifts and improve baseline stability. Removing dissolved gasses eliminates bubbles before they occur and removes oxygen which can interfere with UV detection methods. The system is available in 1-6 channel systems at analytical flow. For preparative HPLC see DEGASi PREP+. Select the “GPC” version for applications using hexanes and similar organic solvents. See Solvent Compatibility Chart »
  • Stand Alone Vacuum Degasser Systems are specifically designed for HPLC and other fluidic systems. The system removes dissolved gases from the mobile phases to reduce retention time shifts and improve baseline stability. Removing dissolved gasses eliminates bubbles before they occur and removes oxygen which can interfere with UV detection methods. The system is available in 2-5 channel systems at analytical flow rates and preparative up to 100 mL/min. Select this "GPC" version for applications using hexanes and similar organic solvents. See Solvent Compatibility Chart »
  • DEGASi Compact is available with 2, 4 or 6 degassing channels in a housing with only 167 x 56 mm footprint. This is possible due to the development of a new single stage vacuum pump with a small built in control board and new 285 µl Systec AF(tm) vacuum chambers. Closed-loop control with a continuously running vacuum pump gives a very smooth baseline. The speed of the pump is varied to maintain an exact vacuum level inside the vacuum chambers. The degasser is equipped with built in error detection functionalities. A bi-color diode on the front panel gives information about the performance. See Solvent Compatibility Chart »
  • The new Stand Alone Vacuum Degasser Systems are specifically designed for HPLC, SPR and other fluidic systems. The system removes dissolved gases from the mobile phases to reduce retention time shifts and improve baseline stability. Removing dissolved gasses eliminates bubbles before they occur and removes oxygen which can interfere with UV detection methods. The system is available in 1-6 channel systems at analytical flow. For preparative HPLC see DEGASi PREP+. Select this "GPC" version for applications using hexanes and similar organic solvents. See Solvent Compatibility Chart »
  • The new Stand Alone Vacuum Degasser Systems are specifically designed for HPLC, SPR and other fluidic systems. The system removes dissolved gases from the mobile phases to reduce retention time shifts and improve baseline stability. Removing dissolved gasses eliminates bubbles before they occur and removes oxygen which can interfere with UV detection methods. The system is available in 1-6 channel systems at analytical flow. For preparative HPLC see DEGASi PREP+. Select the “GPC” version for applications using hexanes and similar organic solvents. See Solvent Compatibility Chart »
  • The new Stand Alone Vacuum Degasser Systems are specifically designed for HPLC, SPR and other fluidic systems. The system removes dissolved gases from the mobile phases to reduce retention time shifts and improve baseline stability. Removing dissolved gasses eliminates bubbles before they occur and removes oxygen which can interfere with UV detection methods. The system is available in 1-6 channel systems at analytical flow. For preparative HPLC see DEGASi PREP+. Select this "GPC" version for applications using hexanes and similar organic solvents. See Solvent Compatibility Chart »
  • Text kommer ... See Solvent Compatibility Chart »
Go to Top