• The DEGASi® Plus UltraNano degasser is optimised for ultra-low flow rates of aqueous and organic liquids up to 25 μL/min. The port design is 10-32 Coned for connection of tubing with OD ranging from 1/32” to 1/16”. This degasser is equipped with 1-5 chambers with biocompatible flow path of only 6 μL for aqueous-organic liquids but is not compatible with hexane and similar organic solvents. As with all DEGASi® Integration degassers, there is an output signal for the vacuum level, and you can expect very silent and trouble-free operation for many years. It is easy to exchange solvents in the degasser thanks to the low swept volume and efficient design of each channel. The internal patented closed-loop vacuum control assures ultra-stable degassing performance that minimize noise in your high-precision system. The degasser comes with advanced leak and error detection functions and three indicator LEDs to show current status. The housing occupies a reduced bench space (261 x 70 x 125 mm) and is easy to access for replacement of parts. The degasser is fully compatible with CE and RoHS directives. See Solvent Compatibility Chart »
    Select options This product has multiple variants. The options may be chosen on the product page Details
  • The Biotech Solvent Recycler is a completely stand-alone device with an integrated display to show current input and settings, and control keys to easily set its operational parameters. It is typically externally powered via 5V DC, but can also be powered and programmed via a USB connected computer running a terminal software application. The Biotech Solvent Recycler can reduce the mobile phase in isocratic HPLC for up to 90% by redirecting uncontaminated mobile phase into the container. The level of the input signal and setting parameters are displayed on a well-read four-digit LCD display. Valve position and the current display mode are indicated by LEDs placed next to the display. Instrument functions are operated via a membrane keyboard with six keys. Setting of operating parameters and online device activity tracking can also be performed from a PC using any terminal application. Its analog input accepts unipolar and bipolar signals in ranges of ± 1V or ±100 mV alternatively. Analog-to-digital converter provides data for further processing in embedded microcontroller. TTL (contact closure) input is used for the auto-zero function. This model has a PEEK solvent flow path, but the Biotech Solvent Recycler is also available with wetted material in PTFE.
  • The Biotech Solvent Recycler is a completely stand-alone device with an integrated display to show current input and settings, and control keys to easily set its operational parameters. It is typically externally powered via 5V DC, but can also be powered and programmed via a USB connected computer running a terminal software application. The Biotech Solvent Recycler can reduce the mobile phase in isocratic HPLC for up to 90% by redirecting uncontaminated mobile phase into the container. The level of the input signal and setting parameters are displayed on a well-read four-digit LCD display. Valve position and the current display mode are indicated by LEDs placed next to the display. Instrument functions are operated via a membrane keyboard with six keys. Setting of operating parameters and online device activity tracking can also be performed from a PC using any terminal application. Its analog input accepts unipolar and bipolar signals in ranges of ± 1V or ±100 mV alternatively. Analog-to-digital converter provides data for further processing in embedded microcontroller. TTL (contact closure) input is used for the auto-zero function. This model has a PTFE solvent flow path, but the Biotech Solvent Recycler is also available with wetted material in PEEK.
  • The SmartSaver™ solvent recycler from Biotech Fluidics saves up to 90% of mobile phase by redirection of the pure solvent to the solvent reservoir during the isocratic HPLC. Can be used with almost all manufacturers equipment and detectors as UV, fluorescens etc. SmartSaver™ brings quite new approach to solvent recycler design. Very compact instrument is powered directly from chromatography data system PC, no power adapter is required. User friendly software is provided to configure the parameters, and to perform on-line monitoring/audit trail. Analog input allows unipolar or bipolar operation within range of ± 1V. TTL/contact closure can be configured as start, auto-zero or valve position control input. This model has a PEEK solvent flow path, but the SmartSaver™ is also available with wetted material in PTFE.
  • The SmartSaver™ solvent recycler from Biotech Fluidics saves up to 90% of mobile phase by redirection of the pure solvent to the solvent reservoir during the isocratic HPLC. Can be used with almost all manufacturers equipment and detectors as UV, fluorescens etc. SmartSaver™ brings quite new approach to solvent recycler design. Very compact instrument is powered directly from chromatography data system PC, no power adapter is required. User friendly software is provided to configure the parameters, and to perform on-line monitoring/audit trail. Analog input allows unipolar or bipolar operation within range of ± 1V. TTL/contact closure can be configured as start, auto-zero or valve position control input. This model has a PTFE solvent flow path, but the SmartSaver™ is also available with wetted material in PEEK.