• Our Bottom Mount Dual-Stage Pump (DST) with Constant Performance PCB is a vacuum control system for use with IDEX film degassing chambers. The system includes a DST vacuum pump and a controller PCB that operates in two modes:
    • Similar to “Constant Vacuum” degasser pumps, the control system will maintain vacuum levels at a user-defined setpoint (default 120mmHg).
    • The Constant Performance algorithm allows the user to set a flow rate and desired efficiency, from which the control algorithms will determine the nominal vacuum level.
    With this patent pending algorithm in our Constant Performance Degassing Pump System, the user gains the following benefits:
    • A Means To Select A Given Efficiency Of Degassing For Any HPLC System
    • Direct Link Between The Chromatographic Method Flow Rate And Optimal Vacuum Level.
    • Consistent Degassing Efficiency For Flow Rates 0-10mL/Min
    • Operates At Highest Possible Pressure Minimizing Solvent Loss To The Laboratory Atmosphere.
    • Reduction Of Mobile Phase Concentration Changes Due To Pervaporation
    • Reduced Vacuum Pump Wear Due To Lower Pump RPM
    Combine this with our Film Degasser to get a revolutionary intelligent user control for HPLC degassing that provides more performance, more efficiency and more control for instrument reliability.
  • Our Side Mount Dual-Stage Pump (DST) with Constant Performance PCB is a vacuum control system for use with IDEX film degassing chambers. The system includes a DST vacuum pump and a controller PCB that operates in two modes:
    • Similar to “Constant Vacuum” degasser pumps, the control system will maintain vacuum levels at a user-defined setpoint (default 120mmHg).
    • The Constant Performance algorithm allows the user to set a flow rate and desired efficiency, from which the control algorithms will determine the nominal vacuum level.
    With this patent pending algorithm in our Constant Performance Degassing Pump System, the user gains the following benefits:
    • A Means To Select A Given Efficiency Of Degassing For Any HPLC System
    • Direct Link Between The Chromatographic Method Flow Rate And Optimal Vacuum Level.
    • Consistent Degassing Efficiency For Flow Rates 0-10mL/Min
    • Operates At Highest Possible Pressure Minimizing Solvent Loss To The Laboratory Atmosphere.
    • Reduction Of Mobile Phase Concentration Changes Due To Pervaporation
    • Reduced Vacuum Pump Wear Due To Lower Pump RPM
    Combine this with our Film Degasser to get a revolutionary intelligent user control for HPLC degassing that provides more performance, more efficiency and more control for instrument reliability.
  • Our Degassing Vacuum Control System is designed for simple plug and play operation into most of our degassing chambers. Simply provide 24DC and the system will automatically provide vacuum to the specified vacuum level. Built in continuous head purges ensure that moisture and vapor are swept out of the pump to maintain consistent performance. An optional connector is available for LED error outputs. This all new generation of pumps is characterized of being almost entirely silent - a remarkable upgrade from older versions. It’s also lighter and operates with less vibrations.
  • Our Degassing Vacuum Control System is designed for simple plug and play operation into most of our degassing chambers. Simply provide 24DC and the system will automatically provide vacuum to the specified vacuum level. Built in continuous head purges ensure that moisture and vapor are swept out of the pump to maintain consistent performance. An optional connector is available for LED error outputs. This all new generation of pumps is characterized of being almost entirely silent - a remarkable upgrade from older versions. It’s also lighter and operates with less vibrations. Errors Detected: 1 Pumpdown: Prep_Unable to reach 110 mmHg in 10 minutes., Analytical_Unable to reach 80 mmH6 in 10 minutes, 2 High Vacuum: Prep_Vacuum more than 110 mmHg for more than 6 min in the running state (after pump down)., Analytical_Vacuum more than 80 mmHg for more than 6 min in the running state (after pump down)., 3 Sensor Signal: Sensor Failure Detected, sensor signal less than 25 mmHg. LED Indicators or Optional Errors Output: Electrical Output _ 10mA @ 5VDC, Blinking Rate_1 second on, 1 second off, Power on, vacuum above control range: Red blinking, Vacuum reaches upper control range: Green, Solid,Error Condition, Shutdown: Red Solid.
  • Our Degassing Vacuum Control System is designed for simple plug and play operation into most of our degassing chambers. Simply provide 24DC and the system will automatically provide vacuum to the specified vacuum level. Built in continuous head purges ensure that moisture and vapor are swept out of the pump to maintain consistent performance. An optional connector is available for LED error outputs. This all new generation of pumps is characterized of being almost entirely silent - a remarkable upgrade from older versions. It’s also lighter and operates with less vibrations. Errors Detected: 1 Pumpdown: Prep_Unable to reach 110 mmHg in 10 minutes., Analytical_Unable to reach 80 mmH6 in 10 minutes, 2 High Vacuum: Prep_Vacuum more than 110 mmHg for more than 6 min in the running state (after pump down)., Analytical_Vacuum more than 80 mmHg for more than 6 min in the running state (after pump down)., 3 Sensor Signal: Sensor Failure Detected, sensor signal less than 25 mmHg. LED Indicators or Optional Errors Output: Electrical Output _ 10mA @ 5VDC, Blinking Rate_1 second on, 1 second off, Power on, vacuum above control range: Red blinking, Vacuum reaches upper control range: Green, Solid,Error Condition, Shutdown: Red Solid.
  • Our Degassing Vacuum Control System is designed for simple plug and play operation into most of our degassing chambers. Simply provide 24DC and the system will automatically provide vacuum to the specified vacuum level. Built in continuous head purges ensure that moisture and vapor are swept out of the pump to maintain consistent performance. An optional connector is available for LED error outputs. This all new generation of pumps is characterized of being almost entirely silent - a remarkable upgrade from older versions. It’s also lighter and operates with less vibrations. Errors Detected: 1 Pumpdown: Prep_Unable to reach 110 mmHg in 10 minutes., Analytical_Unable to reach 80 mmH6 in 10 minutes, 2 High Vacuum: Prep_Vacuum more than 110 mmHg for more than 6 min in the running state (after pump down)., Analytical_Vacuum more than 80 mmHg for more than 6 min in the running state (after pump down)., 3 Sensor Signal: Sensor Failure Detected, sensor signal less than 25 mmHg. LED Indicators or Optional Errors Output: Electrical Output _ 10mA @ 5VDC, Blinking Rate_1 second on, 1 second off, Power on, vacuum above control range: Red blinking, Vacuum reaches upper control range: Green, Solid,Error Condition, Shutdown: Red Solid.
  • 9000-1585 is a controlled vacuum source assembly that includes a single stage vacuum pump and a PCB controller to maintain vacuum levels. There is a connector for optional external LED indicators or error outputs
  • The Dual Stage Pump (DST) is a vacuum control system for use with IDEX degassing chambers and PCB control systems. The analytical version is designed for standard degassing chambers and fluids. The pump is also available in side mount versions.
  • Old version of pump. Recommended to replace the pump with P/N 9000-1471. Systec ZHCR Vacuum Pump, Analytical, bottom mounted. Replaced by 9000-1471 or 9000-1892
  • The Dual Stage Pump (DST) is a vacuum control system for use with IDEX degassing chambers and PCB control systems. The analytical version is designed for standard degassing chambers and fluids. The pump is also available in side mount versions.
  • The Dual Stage Pump (DST) is a vacuum control system for use with IDEX degassing chambers and PCB control systems. The analytical version is designed for standard degassing chambers and fluids. The pump is also available in side mount versions. REPLACED BY 9000-2061.
  • The Dual Stage Pump (DST) is a vacuum control system for use with IDEX degassing chambers and PCB control systems. The prep versions are designed to handle high vapor loads from high flow rate chambers or fluids with low vapor pressure that will cause increased solvent pervaporation through the membrane. The pump is also available in side mount versions.
Go to Top